Technical parameters

Door leaf:62 mm galvanized flexible sheet (1,0 mm thick)
Door frame:100 mm galvanized sheet (1,5 mm thick)
Threshold:20/35 mm stainless steel profile
Hinges:Screwed, painted
Purpose:Private houses, institutions, technical premises

 

Qualitative parameters

Wall opening:..<1030x<..2220 ..<1367x<..2528
Construction dimensions:from ..<10x<..22 iki ..<13,57x<..25,18
Fire resistance:EI230-C5, EW30-C5, E30-C5
Smoke control:Sa-C5 ir S200-C5
Thermal resistance:U=1,6 W/m².K/U=1,2 W/m².K
Sound insulation:Rw=37 dB
Wind load:C5
Water Resistance:6A
Air permeability:4 class
Burglar resistance:3 class
Resistance to repeated opening and closing:8 class(1000.000 cycles)
Mechanical durability:3 class
Warranty:2 year